Edust Lifting Plate Le

> ε Dust Lifting Plate

> ε Dust Lifting Plate

ELECTROSTATIC For Lifting Shoeprint on Paper
The Lifting Plate Kit contains one Acrylic Plate 520 x 420 mm with Aluminum ground plate, one light weight carrying case, one double Cable with yellow Alligator Clips for ground connection and a Black Probe for discharging the lifting film. 

The weight of the lifting plate with all accessories is only one kilogram.

High Voltage εDust+ Unit is not included in this kit.
For Lifting Shoeprint on Paper. The Lifting Plate works well with our Electrostatic Dust Print Lifter εDust and is designed for lifting shoe-prints on paper. 

Very often, the best shoeprints on paper are the invisible prints, and with this plate you can secure these prints very easily with a top quality result.

Instead of bringing everything found on the crime scene into the laboratory for search and security, you can now do this directly at the crime scene. Less unnecessary work with packing and registration of the evidence, will save you a lot of time.


Safety and hazard information. Danger high
voltage, only to be used by trained personnel.

The unitproduces up to 12000 volts with a low
current stress, but can potentially cause an
electrical shock.

Do not touch the lifting film, high voltage probe

or ground plate while the power is active

> The Lifting Process

Place the ground plate under εDust+ Unit as we show. Connect the red cable with a High Voltage Probe and connect to the εDust+.

After that, connect the yellow Double Cable to the εDust+.

Connect the yellow cable with the Alligator Clip to the ground connection on the underside of the plate.
Place the paper you suspect has shoeprints on the lifting plate.
Put a suitable size of the lifting film over suspect shoe prints with the black surface facing the downburst to the Lifting Plate.
Applying lifting film to lifting plate
Switch on the εDust+ Unit and apply the electrostatic energy to the lifting film by pointing the red cable probe at the film. 

Air bubbles between the film and the object can easily be reduced with the “Plastic Flattener”.



To discharge the electrical lifting film.

Switch off the εDust+ Unit and use the black Probe from the Double yellow cable and apply the Probe to the lifting film. 

It, at this moment, is connected to the ground via a double cable. This is for eliminating getting an electrical shock.
Charging lifting film
Examining lifting film with versa light max
Turn around the lifting film and the lifted prints can now be examined and photographed.

We use the Versa Light MAX to get low oblique light to get a clear, good picture of the footprint.